This study evaluates the API 650 design procedure for steel storage tanks, incorporating nonlinear dynamic analysis with large deformation effects. Focusing on seismic vulnerability, the case study examines storage tanks proposed for construction in Naples, Italy, assessing their performance under site-specific seismic conditions. A target spectrum and 20 earthquake records were selected to reflect regional seismic characteristics. Initial tank thicknesses were calculated using API 650 guidelines and subsequently analyzed through nonlinear time-history simulations in SAP2000. Results reveal that thicknesses derived from API 650s linear average spectrum equations are insufficient for real seismic demands. Through a trial-and-error methodology, optimal thicknesses were determined to ensure satisfactory performance across all seismic records. Key findings highlight significant variations in mode participation, the frequent occurrence of elephant-foot buckling in tanks with lower H/R ratios, and the limitations of linear spectral analysis for realistic earthquake scenarios. Given the vital role of storage tanks in the oil and gas industry, this study emphasizes the need to integrate nonlinear time history analysis into design processes to enhance seismic resilience, particularly in high-risk regions.

Assessment of Steel Storage Tank Thickness Obtained from the API 650 Design Procedure Through Nonlinear Dynamic Analysis, Accounting for Large Deformation Effects

Roberto Nascimbene
2025-01-01

Abstract

This study evaluates the API 650 design procedure for steel storage tanks, incorporating nonlinear dynamic analysis with large deformation effects. Focusing on seismic vulnerability, the case study examines storage tanks proposed for construction in Naples, Italy, assessing their performance under site-specific seismic conditions. A target spectrum and 20 earthquake records were selected to reflect regional seismic characteristics. Initial tank thicknesses were calculated using API 650 guidelines and subsequently analyzed through nonlinear time-history simulations in SAP2000. Results reveal that thicknesses derived from API 650s linear average spectrum equations are insufficient for real seismic demands. Through a trial-and-error methodology, optimal thicknesses were determined to ensure satisfactory performance across all seismic records. Key findings highlight significant variations in mode participation, the frequent occurrence of elephant-foot buckling in tanks with lower H/R ratios, and the limitations of linear spectral analysis for realistic earthquake scenarios. Given the vital role of storage tanks in the oil and gas industry, this study emphasizes the need to integrate nonlinear time history analysis into design processes to enhance seismic resilience, particularly in high-risk regions.
2025
nonlinear dynamic analysis; spectral analysis; API 650; steel storage tanks; seismic vulnerability; elephant-foot buckling; oil and gas industry
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12076/19757
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact