Urbanisation and climate change are increasing thermal stress in cities, intensifying the Urban Heat Island (UHI) effect and creating challenges for urban liveability, public health, and climate resilience. Urban Green Infrastructure (UGI) is widely recognised as a nature-based adaptation strategy; however, its thermal performance depends on interactions among vegetation characteristics, solar radiation, atmospheric conditions, and urban morphology. This doctoral thesis develops an integrated experimental and numerical framework to characterise and interpret vegetation-related effects on urban microclimate and outdoor thermal comfort. The methodology combines experimental monitoring, Computational Fluid Dynamics (CFD), Reduced-Order Modelling (ROM), and Global Sensitivity Analysis (GSA), linking real-world observations with controlled investigation of the physical mechanisms and parameter dependencies governing vegetation–atmosphere interactions. The experimental component consists of a multi-year field monitoring campaign conducted in Milan, Italy, during the summers of 2023–2025, considering different combinations of surface cover and solar exposure. Measurements of air temperature, relative humidity, wind speed, global radiation, radiative fluxes, and globe temperature were used to derive Mean Radiant Temperature (MRT) and the Universal Thermal Climate Index (UTCI). A structured workflow integrating meteorological classification, temporal filtering, data availability assessment, instrumental traceability, aggregation strategies, and statistical analysis enabled comparable interpretation of microclimatic and thermal comfort responses across the multi-year dataset. The numerical component develops a physics-based CFD workflow representing coupled airflow, turbulence, heat and moisture transfer, radiation, leaf energy balance, and vegetation–atmosphere exchange. POD-GPR surrogate models were subsequently developed to reproduce the dominant thermo-fluid and UTCI responses of the CFD database while substantially reducing the computational cost of parametric exploration. The resulting ROM framework enabled variance-based GSA of six environmental and vegetation parameters, quantifying both direct and interaction effects across global and local quantities of interest. The results demonstrate that radiative exposure is the primary driver of outdoor thermal comfort differences under monitored summer daytime conditions. Solar exposure produces the largest variations in MRT and UTCI, whereas differences in air temperature and relative humidity among surface–exposure conditions are comparatively smaller. Numerical analyses show that vegetation performance emerges from interacting radiative, aerodynamic, structural, and physiological processes. Incoming shortwave radiation dominates mean and upper-tail UTCI responses, Leaf Area Density (LAD) becomes increasingly influential under lower-tail and canopy-protected conditions, inlet velocity primarily governs airflow-related responses, and stomatal resistance contributes to coupled temperature and moisture behaviour. Overall, this thesis proposes a transferable framework integrating field observations, physics-based modelling, computationally efficient surrogate models, and variance-based sensitivity analysis. The framework supports performance-based UGI assessment centred on radiation-sensitive thermal comfort indicators such as MRT and UTCI.

L’urbanizzazione e il cambiamento climatico stanno intensificando lo stress termico nelle città e l’effetto dell’Isola di Calore Urbana (Urban Heat Island, UHI), con conseguenze per la vivibilità, la salute pubblica e la resilienza climatica. Le Infrastrutture Verdi Urbane (Urban Green Infrastructure, UGI) costituiscono una strategia di adattamento basata sulla natura, ma le loro prestazioni termiche dipendono dalle interazioni tra vegetazione, radiazione solare, condizioni atmosferiche e morfologia urbana. La tesi sviluppa un quadro metodologico integrato, sperimentale e numerico, per caratterizzare e interpretare gli effetti della vegetazione sul microclima urbano e sul comfort termico outdoor. La metodologia combina monitoraggio in campo, Computational Fluid Dynamics (CFD), Reduced-Order Modelling (ROM) e Global Sensitivity Analysis (GSA), collegando osservazioni in condizioni reali con l’analisi controllata dei processi fisici e delle dipendenze parametriche che regolano le interazioni tra vegetazione e atmosfera. La componente sperimentale comprende una campagna di monitoraggio pluriennale condotta a Milano nelle estati 2023–2025, considerando diverse combinazioni di copertura superficiale ed esposizione solare. Le misure di temperatura dell’aria, umidità relativa, velocità del vento, radiazione globale, flussi radiativi e temperatura globotermometrica sono state utilizzate per determinare la Mean Radiant Temperature (MRT) e l’Universal Thermal Climate Index (UTCI). Un workflow basato su classificazione meteorologica, filtraggio temporale, disponibilità dei dati, tracciabilità strumentale, aggregazione e analisi statistica ha consentito il confronto delle risposte microclimatiche e di comfort termico nel dataset pluriennale. La componente numerica sviluppa un modello CFD dei processi accoppiati di flusso dell’aria, turbolenza, trasferimento di calore e umidità, radiazione, bilancio energetico fogliare e scambi tra vegetazione e atmosfera. Modelli surrogati POD-GPR sono stati quindi impiegati per riprodurre le principali risposte termo-fluidodinamiche e di UTCI del database CFD, riducendo i costi computazionali dell’esplorazione parametrica. Il framework ROM ha permesso di applicare una GSA basata sulla varianza a sei parametri ambientali e vegetazionali, quantificando effetti diretti e interazioni per quantità globali e locali. I risultati mostrano che l’esposizione radiativa è il principale fattore delle differenze di comfort termico outdoor nelle condizioni estive diurne monitorate. L’esposizione solare determina le maggiori variazioni di MRT e UTCI, mentre le differenze di temperatura dell’aria e umidità relativa tra le condizioni di superficie ed esposizione risultano più contenute. Le analisi numeriche evidenziano che le prestazioni della vegetazione derivano dall’interazione tra processi radiativi, aerodinamici, strutturali e fisiologici. La radiazione solare incidente a onde corte domina le risposte medie e superiori della distribuzione dell’UTCI; la Leaf Area Density (LAD) diventa più influente nella parte inferiore della distribuzione e nelle zone protette dalla chioma. La velocità in ingresso controlla principalmente le risposte aerodinamiche, mentre la resistenza stomatica contribuisce al comportamento accoppiato di temperatura e umidità. Nel complesso, la tesi propone un framework trasferibile che integra evidenze sperimentali, modellazione fisica, modelli surrogati efficienti e analisi di sensibilità basata sulla varianza. Il framework supporta una valutazione prestazionale delle UGI incentrata su indicatori di comfort termico sensibili alla radiazione, quali MRT e UTCI.

Un approccio integrato per la valutazione dell'impatto dell'infrastruttura verde urbana sul microclima e sul comfort termico / Bernal Quintero, N.A.. - (2026 Nov 20).

Un approccio integrato per la valutazione dell'impatto dell'infrastruttura verde urbana sul microclima e sul comfort termico

BERNAL QUINTERO, NATALIA ALEXANDRA
2026-11-20

Abstract

Urbanisation and climate change are increasing thermal stress in cities, intensifying the Urban Heat Island (UHI) effect and creating challenges for urban liveability, public health, and climate resilience. Urban Green Infrastructure (UGI) is widely recognised as a nature-based adaptation strategy; however, its thermal performance depends on interactions among vegetation characteristics, solar radiation, atmospheric conditions, and urban morphology. This doctoral thesis develops an integrated experimental and numerical framework to characterise and interpret vegetation-related effects on urban microclimate and outdoor thermal comfort. The methodology combines experimental monitoring, Computational Fluid Dynamics (CFD), Reduced-Order Modelling (ROM), and Global Sensitivity Analysis (GSA), linking real-world observations with controlled investigation of the physical mechanisms and parameter dependencies governing vegetation–atmosphere interactions. The experimental component consists of a multi-year field monitoring campaign conducted in Milan, Italy, during the summers of 2023–2025, considering different combinations of surface cover and solar exposure. Measurements of air temperature, relative humidity, wind speed, global radiation, radiative fluxes, and globe temperature were used to derive Mean Radiant Temperature (MRT) and the Universal Thermal Climate Index (UTCI). A structured workflow integrating meteorological classification, temporal filtering, data availability assessment, instrumental traceability, aggregation strategies, and statistical analysis enabled comparable interpretation of microclimatic and thermal comfort responses across the multi-year dataset. The numerical component develops a physics-based CFD workflow representing coupled airflow, turbulence, heat and moisture transfer, radiation, leaf energy balance, and vegetation–atmosphere exchange. POD-GPR surrogate models were subsequently developed to reproduce the dominant thermo-fluid and UTCI responses of the CFD database while substantially reducing the computational cost of parametric exploration. The resulting ROM framework enabled variance-based GSA of six environmental and vegetation parameters, quantifying both direct and interaction effects across global and local quantities of interest. The results demonstrate that radiative exposure is the primary driver of outdoor thermal comfort differences under monitored summer daytime conditions. Solar exposure produces the largest variations in MRT and UTCI, whereas differences in air temperature and relative humidity among surface–exposure conditions are comparatively smaller. Numerical analyses show that vegetation performance emerges from interacting radiative, aerodynamic, structural, and physiological processes. Incoming shortwave radiation dominates mean and upper-tail UTCI responses, Leaf Area Density (LAD) becomes increasingly influential under lower-tail and canopy-protected conditions, inlet velocity primarily governs airflow-related responses, and stomatal resistance contributes to coupled temperature and moisture behaviour. Overall, this thesis proposes a transferable framework integrating field observations, physics-based modelling, computationally efficient surrogate models, and variance-based sensitivity analysis. The framework supports performance-based UGI assessment centred on radiation-sensitive thermal comfort indicators such as MRT and UTCI.
20-nov-2026
38
SVILUPPO SOSTENIBILE E CAMBIAMENTO CLIMATICO
L’urbanizzazione e il cambiamento climatico stanno intensificando lo stress termico nelle città e l’effetto dell’Isola di Calore Urbana (Urban Heat Island, UHI), con conseguenze per la vivibilità, la salute pubblica e la resilienza climatica. Le Infrastrutture Verdi Urbane (Urban Green Infrastructure, UGI) costituiscono una strategia di adattamento basata sulla natura, ma le loro prestazioni termiche dipendono dalle interazioni tra vegetazione, radiazione solare, condizioni atmosferiche e morfologia urbana. La tesi sviluppa un quadro metodologico integrato, sperimentale e numerico, per caratterizzare e interpretare gli effetti della vegetazione sul microclima urbano e sul comfort termico outdoor. La metodologia combina monitoraggio in campo, Computational Fluid Dynamics (CFD), Reduced-Order Modelling (ROM) e Global Sensitivity Analysis (GSA), collegando osservazioni in condizioni reali con l’analisi controllata dei processi fisici e delle dipendenze parametriche che regolano le interazioni tra vegetazione e atmosfera. La componente sperimentale comprende una campagna di monitoraggio pluriennale condotta a Milano nelle estati 2023–2025, considerando diverse combinazioni di copertura superficiale ed esposizione solare. Le misure di temperatura dell’aria, umidità relativa, velocità del vento, radiazione globale, flussi radiativi e temperatura globotermometrica sono state utilizzate per determinare la Mean Radiant Temperature (MRT) e l’Universal Thermal Climate Index (UTCI). Un workflow basato su classificazione meteorologica, filtraggio temporale, disponibilità dei dati, tracciabilità strumentale, aggregazione e analisi statistica ha consentito il confronto delle risposte microclimatiche e di comfort termico nel dataset pluriennale. La componente numerica sviluppa un modello CFD dei processi accoppiati di flusso dell’aria, turbolenza, trasferimento di calore e umidità, radiazione, bilancio energetico fogliare e scambi tra vegetazione e atmosfera. Modelli surrogati POD-GPR sono stati quindi impiegati per riprodurre le principali risposte termo-fluidodinamiche e di UTCI del database CFD, riducendo i costi computazionali dell’esplorazione parametrica. Il framework ROM ha permesso di applicare una GSA basata sulla varianza a sei parametri ambientali e vegetazionali, quantificando effetti diretti e interazioni per quantità globali e locali. I risultati mostrano che l’esposizione radiativa è il principale fattore delle differenze di comfort termico outdoor nelle condizioni estive diurne monitorate. L’esposizione solare determina le maggiori variazioni di MRT e UTCI, mentre le differenze di temperatura dell’aria e umidità relativa tra le condizioni di superficie ed esposizione risultano più contenute. Le analisi numeriche evidenziano che le prestazioni della vegetazione derivano dall’interazione tra processi radiativi, aerodinamici, strutturali e fisiologici. La radiazione solare incidente a onde corte domina le risposte medie e superiori della distribuzione dell’UTCI; la Leaf Area Density (LAD) diventa più influente nella parte inferiore della distribuzione e nelle zone protette dalla chioma. La velocità in ingresso controlla principalmente le risposte aerodinamiche, mentre la resistenza stomatica contribuisce al comportamento accoppiato di temperatura e umidità. Nel complesso, la tesi propone un framework trasferibile che integra evidenze sperimentali, modellazione fisica, modelli surrogati efficienti e analisi di sensibilità basata sulla varianza. Il framework supporta una valutazione prestazionale delle UGI incentrata su indicatori di comfort termico sensibili alla radiazione, quali MRT e UTCI.
MEREU, RICCARDO
CAUSONE, FRANCESCO
File in questo prodotto:
File Dimensione Formato  
PhD SDC Thesis_Bernal Quintero.pdf

embargo fino al 20/11/2027

Descrizione: Tesi definitiva
Tipologia: Tesi di dottorato
Dimensione 16.94 MB
Formato Adobe PDF
16.94 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12076/27187
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact